Franklin / AIR-SOURCE HEAT PUMP

MST183F25MHAA

MST Series · EPA record 3999985

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3999985. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh22.00
EER2 · BTU/Wh12.50
HSPF2 · BTU/Wh9.80
Cooling capacity · BTU/h19000
Heating capacity at 47°F / 8.3°C · BTU/h20000
Heating capacity at 17°F / −8.3°C · BTU/h15000
Heating capacity at 5°F / −15°C · BTU/h19700
COP at 5°F / −15°C1.90
Equipment / loop typeHP - Mini or Multi Split
Refrigerant / source-reported GWPR-410A (GWP:2088)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

Outdoor-model source rating

EPA reports this outdoor model and its ratings without listing individual indoor units. A complete matched configuration is not available in this record. Do not infer compatibility with a particular indoor unit.

EPA multi-split reporting rules ↗

Outdoor unitMST183F25MHAA
+
Indoor unitIndoor configuration not listed by EPA

AHRI reference 214383439 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for MST183F25MHAA

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3999985EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.90EPA Sep 21, 2026
eer2 btu wh12.50EPA Sep 21, 2026
series nameMST SeriesEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.80EPA Sep 21, 2026
model numberMST183F25MHAAEPA Sep 21, 2026
product typeHP - Mini or Multi SplitEPA Sep 21, 2026
seer2 btu wh22.00EPA Sep 21, 2026
date certified2026-06-13T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerDaikin Comfort Technologies Manufacturing, L.P.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-410A (GWP:2088)EPA Sep 21, 2026
ahri reference number214383439EPA Sep 21, 2026
cooling capacity btu h19000EPA Sep 21, 2026
indoor unit brand nameFRANKLINEPA Sep 21, 2026
outdoor unit brand nameFranklinEPA Sep 21, 2026
date available on market2024-12-08T00:00:00.000EPA Sep 21, 2026
energy star model identifierES_1035638_MST183F25MHAA_03132025031159_29214383439EPA Sep 21, 2026
heating capacity at 5 f btu h19700EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h15000EPA Sep 21, 2026
heating capacity at 47 f btu h20000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026