EG4 / AIR-SOURCE HEAT PUMP

DWLC2-24KR2(US)

EVI HEAT · EPA record 3999857

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3999857. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh21.00
EER2 · BTU/Wh12.50
HSPF2 · BTU/Wh11.00
Cooling capacity · BTU/h22000
Heating capacity at 47°F / 8.3°C · BTU/h27000
Heating capacity at 17°F / −8.3°C · BTU/h22400
Heating capacity at 5°F / −15°C · BTU/h22000
COP at 5°F / −15°C2.05
Equipment / loop typeHP - Mini or Multi Split
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitDWLC2-24KR2(US)
+
Indoor unitDGLA3-24KR2(US)

AHRI reference 216772363 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for DWLC2-24KR2(US)

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3999857EPA Sep 21, 2026
marketsUnited StatesEPA Sep 21, 2026
cop at 5 f2.05EPA Sep 21, 2026
eer2 btu wh12.50EPA Sep 21, 2026
series nameEVI HEATEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh11.00EPA Sep 21, 2026
model numberDWLC2-24KR2(US)EPA Sep 21, 2026
product typeHP - Mini or Multi SplitEPA Sep 21, 2026
seer2 btu wh21.00EPA Sep 21, 2026
date certified2026-05-06T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerEG4 ELECTRONICSEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-32 (GWP:675 | Lower GWP)EPA Sep 21, 2026
ahri reference number216772363EPA Sep 21, 2026
cooling capacity btu h22000EPA Sep 21, 2026
indoor unit brand nameEG4EPA Sep 21, 2026
outdoor unit brand nameEG4EPA Sep 21, 2026
date available on market2025-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberDGLA3-24KR2(US)EPA Sep 21, 2026
energy star model identifierES_1149327_DWLC2-24KR2(US)_01212025065014_29216772363EPA Sep 21, 2026
heating capacity at 5 f btu h22000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h22400EPA Sep 21, 2026
heating capacity at 47 f btu h27000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026