Fraser-Johnston / AIR-SOURCE HEAT PUMP
HL19B2421
RELIANT · EPA record 3990240
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 3990240. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 17.00 |
| EER2 · BTU/Wh | 13.00 |
| HSPF2 · BTU/Wh | 7.80 |
| Cooling capacity · BTU/h | 23000 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23000 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14400 |
| Heating capacity at 5°F / −15°C · BTU/h | 10900 |
| COP at 5°F / −15°C | 1.80 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) |
| Compressor staging | Two-stage |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+HL19B2421Indoor unit
+XAHB36DBAN1Required furnace
Z8ES080B12SMPS1AHRI reference 211769086 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for HL19B2421 →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 3990240 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.80 | EPA Sep 21, 2026 |
| eer2 btu wh | 13.00 | EPA Sep 21, 2026 |
| series name | RELIANT | EPA Sep 21, 2026 |
| cold climate | No | EPA Sep 21, 2026 |
| hspf2 btu wh | 7.80 | EPA Sep 21, 2026 |
| model number | HL19B2421 | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 17.00 | EPA Sep 21, 2026 |
| date certified | 2025-04-11T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Two-stage | EPA Sep 21, 2026 |
| energy star partner | Johnson Controls, Inc. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | Z8ES080B12SMPS1 | EPA Sep 21, 2026 |
| refrigerant with gwp | R-410A (GWP:2088) | EPA Sep 21, 2026 |
| ahri reference number | 211769086 | EPA Sep 21, 2026 |
| cooling capacity btu h | 23000 | EPA Sep 21, 2026 |
| outdoor unit brand name | Fraser-Johnston | EPA Sep 21, 2026 |
| date available on market | 2024-07-09T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | XAHB36DBAN1 | EPA Sep 21, 2026 |
| energy star model identifier | ES_21045_HL19B2421_03292023013150_2951529 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 10900 | EPA Sep 21, 2026 |
| meets most efficient criteria | No | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 14400 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 23000 | EPA Sep 21, 2026 |
| meets peak cooling requirements | Yes | EPA Sep 21, 2026 |
| controls verification procedure cvp test | None | EPA Sep 21, 2026 |