Heil / AIR-SOURCE HEAT PUMP

H5H0V60*K*AAA*

QUIETCOMFORT DELUXE 20 VS HP · EPA record 3971554

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3971554. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh18.50
EER2 · BTU/Wh9.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h56500
Heating capacity at 47°F / 8.3°C · BTU/hNot supplied
Heating capacity at 17°F / −8.3°C · BTU/h56000
Heating capacity at 5°F / −15°C · BTU/h45000
COP at 5°F / −15°C2.08
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitH5H0V60*K*AAA*
+
Indoor unitEVM5X60M21A*+WALLCON
+
Required furnace*96CTN1002122B*

AHRI reference 215677075 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for H5H0V60*K*AAA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3971554EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.08EPA Sep 21, 2026
eer2 btu wh9.00EPA Sep 21, 2026
series nameQUIETCOMFORT DELUXE 20 VS HPEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model numberH5H0V60*K*AAA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh18.50EPA Sep 21, 2026
date certified2025-01-30T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number*96CTN1002122B*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215677075EPA Sep 21, 2026
cooling capacity btu h56500EPA Sep 21, 2026
outdoor unit brand nameHeilEPA Sep 21, 2026
date available on market2024-11-04T00:00:00.000EPA Sep 21, 2026
indoor unit model numberEVM5X60M21A*+WALLCONEPA Sep 21, 2026
energy star model identifierES_1020846_H5H0V60*K*AAA*_10162024033509_76696EPA Sep 21, 2026
heating capacity at 5 f btu h45000EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h56000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026