ACIQ / AIR-SOURCE HEAT PUMP

H5H3V48*K*AAA*

Deluxe 23 VS Heat Pump · EPA record 3966052

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3966052. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh21.00
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh9.50
Cooling capacity · BTU/h45000
Heating capacity at 47°F / 8.3°C · BTU/h48500
Heating capacity at 17°F / −8.3°C · BTU/h40000
Heating capacity at 5°F / −15°C · BTU/h37000
COP at 5°F / −15°C2.00
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitH5H3V48*K*AAA*
+
Indoor unitEA*5X61M21A*+WALLCON
+
Required furnace*96CTN0802120B*

AHRI reference 216636185 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for H5H3V48*K*AAA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3966052EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.00EPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series nameDeluxe 23 VS Heat PumpEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.50EPA Sep 21, 2026
model numberH5H3V48*K*AAA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh21.00EPA Sep 21, 2026
date certified2026-07-16T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number*96CTN0802120B*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number216636185EPA Sep 21, 2026
cooling capacity btu h45000EPA Sep 21, 2026
outdoor unit brand nameACIQEPA Sep 21, 2026
date available on market2024-11-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberEA*5X61M21A*+WALLCONEPA Sep 21, 2026
energy star model identifierES_1020846_H5H3V48*K*AAA*_12202024143646_20216636185EPA Sep 21, 2026
heating capacity at 5 f btu h37000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h40000EPA Sep 21, 2026
heating capacity at 47 f btu h48500EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026