BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN060**AA*

2-STAGE 18 SEER HP · EPA record 3950686

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3950686. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh11.70
HSPF2 · BTU/Wh8.10
Cooling capacity · BTU/h55000
Heating capacity at 47°F / 8.3°C · BTU/h59500
Heating capacity at 17°F / −8.3°C · BTU/h38000
Heating capacity at 5°F / −15°C · BTU/h31400
COP at 5°F / −15°C2.18
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingTwo-stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit248TAN060**AA*
+
Indoor unitCVAVA6121XMA*
+
Required furnace935SB60100M21***

AHRI reference 215628006 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 248TAN060**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3950686EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.18EPA Sep 21, 2026
eer2 btu wh11.70EPA Sep 21, 2026
series name2-STAGE 18 SEER HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.10EPA Sep 21, 2026
model number248TAN060**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2025-02-17T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingTwo-stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number935SB60100M21***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215628006EPA Sep 21, 2026
cooling capacity btu h55000EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2024-11-04T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCVAVA6121XMA*EPA Sep 21, 2026
energy star model identifierES_1020846_248TAN060**AA*_09172024015617_8888068EPA Sep 21, 2026
heating capacity at 5 f btu h31400EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h38000EPA Sep 21, 2026
heating capacity at 47 f btu h59500EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026