TCL / AIR-SOURCE HEAT PUMP

TSH12HEI2NAO0T24*

DUCT-single · EPA record 3893773

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3893773. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh19.00
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh8.40
Cooling capacity · BTU/h11000
Heating capacity at 47°F / 8.3°C · BTU/h12000
Heating capacity at 17°F / −8.3°C · BTU/h10200
Heating capacity at 5°F / −15°C · BTU/h8800
COP at 5°F / −15°C1.80
Equipment / loop typeHP - Mini or Multi Split
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

Outdoor-model source rating

EPA reports this outdoor model and its ratings without listing individual indoor units. A complete matched configuration is not available in this record. Do not infer compatibility with a particular indoor unit.

EPA multi-split reporting rules ↗

Outdoor unitTSH12HEI2NAO0T24*
+
Indoor unitIndoor configuration not listed by EPA

AHRI reference 216706242 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for TSH12HEI2NAO0T24*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3893773EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.80EPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series nameDUCT-singleEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.40EPA Sep 21, 2026
model numberTSH12HEI2NAO0T24*EPA Sep 21, 2026
product typeHP - Mini or Multi SplitEPA Sep 21, 2026
seer2 btu wh19.00EPA Sep 21, 2026
date certified2025-09-25T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerTCL Air conditioner (Zhong Shan) Co., Ltd.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number216706242EPA Sep 21, 2026
cooling capacity btu h11000EPA Sep 21, 2026
indoor unit brand nameTCLEPA Sep 21, 2026
outdoor unit brand nameTCLEPA Sep 21, 2026
date available on market2025-01-01T00:00:00.000EPA Sep 21, 2026
energy star model identifierES_1126578_TSH12HEI2NAO0T24*_01012025005031_23216706242EPA Sep 21, 2026
heating capacity at 5 f btu h8800EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h10200EPA Sep 21, 2026
heating capacity at 47 f btu h12000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026