Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H0V24*K*AAA*

Deluxe 20 VS Heat Pump · EPA record 3799783

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3799783. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh17.00
EER2 · BTU/Wh10.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h23800
Heating capacity at 47°F / 8.3°C · BTU/h23400
Heating capacity at 17°F / −8.3°C · BTU/h19800
Heating capacity at 5°F / −15°C · BTU/h16500
COP at 5°F / −15°C2.00
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit(C,H,T)5H0V24*K*AAA*
+
Indoor unitEA*5X37M17A*+WALLCON
+
Required furnace*80CSU0601716A*

AHRI reference 215667738 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for (C,H,T)5H0V24*K*AAA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3799783EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.00EPA Sep 21, 2026
eer2 btu wh10.00EPA Sep 21, 2026
series nameDeluxe 20 VS Heat PumpEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model number(C,H,T)5H0V24*K*AAA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh17.00EPA Sep 21, 2026
date certified2026-05-01T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number*80CSU0601716A*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215667738EPA Sep 21, 2026
cooling capacity btu h23800EPA Sep 21, 2026
outdoor unit brand nameKenmoreEPA Sep 21, 2026
date available on market2024-11-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberEA*5X37M17A*+WALLCONEPA Sep 21, 2026
energy star model identifierES_1020846_(C,H,T)5H0V24*K*AAA*_11122024173017_1472399EPA Sep 21, 2026
heating capacity at 5 f btu h16500EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h19800EPA Sep 21, 2026
heating capacity at 47 f btu h23400EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026