Kenmore / AIR-SOURCE HEAT PUMP
(C,H,T)5H3V48*K*AAA*
Deluxe 23 VS Heat Pump · EPA record 3724930
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 3724930. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 21.00 |
| EER2 · BTU/Wh | 11.50 |
| HSPF2 · BTU/Wh | 8.10 |
| Cooling capacity · BTU/h | 45500 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52500 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 43000 |
| Heating capacity at 5°F / −15°C · BTU/h | 38000 |
| COP at 5°F / −15°C | 1.95 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+(C,H,T)5H3V48*K*AAA*Indoor unit
+EVM5X60M24A*+WALLCONRequired furnace
*80CTL1102120B*AHRI reference 215937482 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for (C,H,T)5H3V48*K*AAA* →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 3724930 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.95 | EPA Sep 21, 2026 |
| eer2 btu wh | 11.50 | EPA Sep 21, 2026 |
| series name | Deluxe 23 VS Heat Pump | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.10 | EPA Sep 21, 2026 |
| model number | (C,H,T)5H3V48*K*AAA* | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 21.00 | EPA Sep 21, 2026 |
| date certified | 2026-06-29T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Carrier Corporation | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | *80CTL1102120B* | EPA Sep 21, 2026 |
| refrigerant with gwp | R-454B (GWP:470 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 215937482 | EPA Sep 21, 2026 |
| cooling capacity btu h | 45500 | EPA Sep 21, 2026 |
| outdoor unit brand name | Kenmore | EPA Sep 21, 2026 |
| date available on market | 2024-11-01T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | EVM5X60M24A*+WALLCON | EPA Sep 21, 2026 |
| energy star model identifier | ES_1020846_(C,H,T)5H3V48*K*AAA*_10252024023045_3373318 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 38000 | EPA Sep 21, 2026 |
| meets most efficient criteria | No | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 43000 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 52500 | EPA Sep 21, 2026 |
| meets peak cooling requirements | No | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |