Keeprite / AIR-SOURCE HEAT PUMP
C5H0V36*K*AAA*
ProComfort 20 VS HP · EPA record 3717369
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 3717369. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 18.50 |
| EER2 · BTU/Wh | 10.50 |
| HSPF2 · BTU/Wh | 9.00 |
| Cooling capacity · BTU/h | 34800 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34400 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29800 |
| Heating capacity at 5°F / −15°C · BTU/h | 24800 |
| COP at 5°F / −15°C | 1.92 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+C5H0V36*K*AAA*Indoor unit
+EA*5X61M21A*+WALLCONRequired furnace
*96CTN1002122B*AHRI reference 215669609 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for C5H0V36*K*AAA* →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 3717369 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.92 | EPA Sep 21, 2026 |
| eer2 btu wh | 10.50 | EPA Sep 21, 2026 |
| series name | ProComfort 20 VS HP | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 9.00 | EPA Sep 21, 2026 |
| model number | C5H0V36*K*AAA* | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 18.50 | EPA Sep 21, 2026 |
| date certified | 2025-02-17T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Carrier Corporation | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | *96CTN1002122B* | EPA Sep 21, 2026 |
| refrigerant with gwp | R-454B (GWP:470 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 215669609 | EPA Sep 21, 2026 |
| cooling capacity btu h | 34800 | EPA Sep 21, 2026 |
| outdoor unit brand name | Keeprite | EPA Sep 21, 2026 |
| date available on market | 2024-11-04T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | EA*5X61M21A*+WALLCON | EPA Sep 21, 2026 |
| energy star model identifier | ES_1020846_C5H0V36*K*AAA*_10162024033114_4018310 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 24800 | EPA Sep 21, 2026 |
| meets most efficient criteria | Yes | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 29800 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 34400 | EPA Sep 21, 2026 |
| meets peak cooling requirements | No | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |