ECOER / AIR-SOURCE HEAT PUMP

EODA18H-2436BAA

ESi Decades Extreme · EPA record 3649590

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3649590. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh17.20
EER2 · BTU/Wh10.80
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h33600
Heating capacity at 47°F / 8.3°C · BTU/h35000
Heating capacity at 17°F / −8.3°C · BTU/h27000
Heating capacity at 5°F / −15°C · BTU/h24600
COP at 5°F / −15°C1.95
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-410A (GWP:2088)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitEODA18H-2436BAA
+
Indoor unitEAHAEC-36

AHRI reference 215722680 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for EODA18H-2436BAA

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3649590EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.95EPA Sep 21, 2026
eer2 btu wh10.80EPA Sep 21, 2026
series nameESi Decades ExtremeEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model numberEODA18H-2436BAAEPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh17.20EPA Sep 21, 2026
date certified2026-08-05T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerEcoer Inc.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-410A (GWP:2088)EPA Sep 21, 2026
ahri reference number215722680EPA Sep 21, 2026
cooling capacity btu h33600EPA Sep 21, 2026
outdoor unit brand nameECOEREPA Sep 21, 2026
date available on market2024-04-10T00:00:00.000EPA Sep 21, 2026
indoor unit model numberEAHAEC-36EPA Sep 21, 2026
energy star model identifierES_1141089_EODA18H-2436BAA_09222024083002_4399146EPA Sep 21, 2026
heating capacity at 5 f btu h24600EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h27000EPA Sep 21, 2026
heating capacity at 47 f btu h35000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026