Lennox / AIR-SOURCE HEAT PUMP

EL16KP1-030-230A**

ELITE EL16KP1 Series · EPA record 3649566

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3649566. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh15.50
EER2 · BTU/Wh12.80
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h29200
Heating capacity at 47°F / 8.3°C · BTU/h26800
Heating capacity at 17°F / −8.3°C · BTU/h17200
Heating capacity at 5°F / −15°C · BTU/h13500
COP at 5°F / −15°C1.96
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitEL16KP1-030-230A**
+
Indoor unitCK40HT-30B-**+TDR
+
Required furnaceML296UH070XV36B*

AHRI reference 215712765 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for EL16KP1-030-230A**

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3649566EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.96EPA Sep 21, 2026
eer2 btu wh12.80EPA Sep 21, 2026
series nameELITE EL16KP1 SeriesEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberEL16KP1-030-230A**EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.50EPA Sep 21, 2026
date certified2025-10-27T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerLennox IndustriesEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberML296UH070XV36B*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215712765EPA Sep 21, 2026
cooling capacity btu h29200EPA Sep 21, 2026
outdoor unit brand nameLennoxEPA Sep 21, 2026
date available on market2024-10-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCK40HT-30B-**+TDREPA Sep 21, 2026
energy star model identifierES_1082495_EL16KP1-030-230A**_09212024013635_4477279EPA Sep 21, 2026
heating capacity at 5 f btu h13500EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h17200EPA Sep 21, 2026
heating capacity at 47 f btu h26800EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026