AZV7SA2410A*
AZV7SA · EPA record 3625393
Performance & equipment details
Values below belong to EPA record 3625393. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 19.00 |
| EER2 · BTU/Wh | 11.00 |
| HSPF2 · BTU/Wh | 8.60 |
| Cooling capacity · BTU/h | 23200 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23200 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15800 |
| Heating capacity at 5°F / −15°C · BTU/h | 17000 |
| COP at 5°F / −15°C | 2.00 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 132 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 22.4 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 147 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
AZV7SA2410A*CA*EA3022*3A*A*VT800804C*A*AHRI reference 215434033 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for AZV7SA2410A* →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 3625393 | EPA Sep 21, 2026 |
| markets | United States | EPA Sep 21, 2026 |
| cop at 5 f | 2.00 | EPA Sep 21, 2026 |
| eer2 btu wh | 11.00 | EPA Sep 21, 2026 |
| series name | AZV7SA | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.60 | EPA Sep 21, 2026 |
| model number | AZV7SA2410A* | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 19.00 | EPA Sep 21, 2026 |
| date certified | 2026-01-06T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Daikin Comfort Technologies Manufacturing, L.P. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | A*VT800804C*A* | EPA Sep 21, 2026 |
| refrigerant with gwp | R-32 (GWP:675 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 215434033 | EPA Sep 21, 2026 |
| cooling capacity btu h | 23200 | EPA Sep 21, 2026 |
| outdoor unit brand name | Amana | EPA Sep 21, 2026 |
| date available on market | 2025-07-23T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | CA*EA3022*3A* | EPA Sep 21, 2026 |
| energy star model identifier | ES_1035638_AZV7SA2410A*_08272024013028_6585197 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 17000 | EPA Sep 21, 2026 |
| meets most efficient criteria | Yes | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 15800 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 23200 | EPA Sep 21, 2026 |
| meets peak cooling requirements | Yes | EPA Sep 21, 2026 |
| controls verification procedure cvp test | DOE Federal CVP Test | EPA Sep 21, 2026 |