BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP · EPA record 3411155

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3411155. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh12.00
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h24200
Heating capacity at 47°F / 8.3°C · BTU/h23800
Heating capacity at 17°F / −8.3°C · BTU/h14500
Heating capacity at 5°F / −15°C · BTU/h11200
COP at 5°F / −15°C1.98
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitPH5SAN524**AA*
+
Indoor unitCVAMA3217XMA*
+
Required furnace8(0,1)*SB42090M17***

AHRI reference 214212541 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for PH5SAN524**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3411155EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.98EPA Sep 21, 2026
eer2 btu wh12.00EPA Sep 21, 2026
series name15 SEER2 HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberPH5SAN524**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2026-02-10T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number8(0,1)*SB42090M17***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number214212541EPA Sep 21, 2026
cooling capacity btu h24200EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2024-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCVAMA3217XMA*EPA Sep 21, 2026
energy star model identifierES_1020846_PH5SAN524**AA*_02022024022750_2520488EPA Sep 21, 2026
heating capacity at 5 f btu h11200EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h14500EPA Sep 21, 2026
heating capacity at 47 f btu h23800EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026