BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · EPA record 3410634

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3410634. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh12.50
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h24200
Heating capacity at 47°F / 8.3°C · BTU/h23600
Heating capacity at 17°F / −8.3°C · BTU/h14700
Heating capacity at 5°F / −15°C · BTU/h11400
COP at 5°F / −15°C2.00
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitGH5SAN524**AA*
+
Indoor unitCVAVA3817XMA*
+
Required furnace8(0,1)*SB36070M17***

AHRI reference 214213973 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for GH5SAN524**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3410634EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.00EPA Sep 21, 2026
eer2 btu wh12.50EPA Sep 21, 2026
series name15 SEER2 HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberGH5SAN524**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2025-01-29T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number8(0,1)*SB36070M17***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number214213973EPA Sep 21, 2026
cooling capacity btu h24200EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2024-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCVAVA3817XMA*EPA Sep 21, 2026
energy star model identifierES_1020846_GH5SAN524**AA*_02022024022703_672752EPA Sep 21, 2026
heating capacity at 5 f btu h11400EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h14700EPA Sep 21, 2026
heating capacity at 47 f btu h23600EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026