BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN024**AA*

PREFERRED 16 SEER2 HP · EPA record 3408406

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3408406. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh15.50
EER2 · BTU/Wh12.00
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h24000
Heating capacity at 47°F / 8.3°C · BTU/h22000
Heating capacity at 17°F / −8.3°C · BTU/h14900
Heating capacity at 5°F / −15°C · BTU/h11600
COP at 5°F / −15°C2.14
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit246SAN024**AA*
+
Indoor unitCAA**3721AM*
+
Required furnace82*SB60090V21***

AHRI reference 214201708 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 246SAN024**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3408406EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.14EPA Sep 21, 2026
eer2 btu wh12.00EPA Sep 21, 2026
series namePREFERRED 16 SEER2 HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model number246SAN024**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.50EPA Sep 21, 2026
date certified2025-01-29T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number82*SB60090V21***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number214201708EPA Sep 21, 2026
cooling capacity btu h24000EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2024-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**3721AM*EPA Sep 21, 2026
energy star model identifierES_1020846_246SAN024**AA*_02022024022237_8610734EPA Sep 21, 2026
heating capacity at 5 f btu h11600EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h14900EPA Sep 21, 2026
heating capacity at 47 f btu h22000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026