Fraser-Johnston / AIR-SOURCE HEAT PUMP
HMH72B341
HMH7 · EPA record 2486020
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 2486020. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 18.50 |
| EER2 · BTU/Wh | 9.50 |
| HSPF2 · BTU/Wh | 8.10 |
| Cooling capacity · BTU/h | 34000 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34000 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25800 |
| Heating capacity at 5°F / −15°C · BTU/h | 24400 |
| COP at 5°F / −15°C | 2.08 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+HMH72B341Indoor unit
+XAFC36DBCN1Required furnace
TM9Y080C16MP11AHRI reference 211386854 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for HMH72B341 →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 2486020 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 2.08 | EPA Sep 21, 2026 |
| eer2 btu wh | 9.50 | EPA Sep 21, 2026 |
| series name | HMH7 | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.10 | EPA Sep 21, 2026 |
| model number | HMH72B341 | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 18.50 | EPA Sep 21, 2026 |
| date certified | 2026-05-01T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Johnson Controls, Inc. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | TM9Y080C16MP11 | EPA Sep 21, 2026 |
| refrigerant with gwp | R-410A (GWP:2088) | EPA Sep 21, 2026 |
| ahri reference number | 211386854 | EPA Sep 21, 2026 |
| cooling capacity btu h | 34000 | EPA Sep 21, 2026 |
| outdoor unit brand name | Fraser-Johnston | EPA Sep 21, 2026 |
| date available on market | 2025-07-24T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | XAFC36DBCN1 | EPA Sep 21, 2026 |
| energy star model identifier | ES_21045_HMH72B341_05112023193102_5106211 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 24400 | EPA Sep 21, 2026 |
| meets most efficient criteria | No | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 25800 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 34000 | EPA Sep 21, 2026 |
| meets peak cooling requirements | Yes | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |