Performance & equipment details
Values below belong to EPA record 2471860. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 15.20 |
| EER2 · BTU/Wh | 11.70 |
| HSPF2 · BTU/Wh | 8.10 |
| Cooling capacity · BTU/h | 22800 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22800 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16000 |
| Heating capacity at 5°F / −15°C · BTU/h | 12700 |
| COP at 5°F / −15°C | 2.20 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) |
| Compressor staging | Two-stage |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+WP15AZ24AJ2NIndoor unit
+TCFZ2417STANMRequired furnace
W951W0403A17UHUAHRI reference 212404499 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for WP15AZ24AJ2N →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 2471860 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 2.20 | EPA Sep 21, 2026 |
| eer2 btu wh | 11.70 | EPA Sep 21, 2026 |
| series name | VERSUS | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.10 | EPA Sep 21, 2026 |
| model number | WP15AZ24AJ2N | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 15.20 | EPA Sep 21, 2026 |
| date certified | 2026-06-03T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Two-stage | EPA Sep 21, 2026 |
| energy star partner | Rheem Sales Company, Inc. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| furnace model number | W951W0403A17UHU | EPA Sep 21, 2026 |
| refrigerant with gwp | R-410A (GWP:2088) | EPA Sep 21, 2026 |
| ahri reference number | 212404499 | EPA Sep 21, 2026 |
| cooling capacity btu h | 22800 | EPA Sep 21, 2026 |
| outdoor unit brand name | WeatherKing | EPA Sep 21, 2026 |
| date available on market | 2023-04-20T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | TCFZ2417STANM | EPA Sep 21, 2026 |
| energy star model identifier | ES_1045829_WP15AZ24AJ2N_04292023083112_5227092 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 12700 | EPA Sep 21, 2026 |
| meets most efficient criteria | No | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 16000 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 22800 | EPA Sep 21, 2026 |
| meets peak cooling requirements | Yes | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |