US EQUIPMENT REFERENCE

SLIMAIR / page 2

72 equipment models and 176 source-listed options. Brand names follow the published records; a shared manufacturer does not imply interchangeable equipment.

RefineClear

72 models · Source-backed US equipment index

A model may have several rated combinations.
SLIMAIRAir-source heat pump

Multiple source series

SHC18VH2AG

4 published source records

18–22SEER2 range
9.5–10.6HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC24AC2AG

1 published source record

18.5SEER2 range
9HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC24AE224V

1 published source record

18.1SEER2 range
9.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC24AE2AG

5 published source records

19–23.5SEER2 range
10–11.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC24AH224V

1 published source record

18.3SEER2 range
10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC24AH2AG

5 published source records

19–22.3SEER2 range
11.6–13.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

Multiple source series

SHC24VE2AG

4 published source records

19–21.5SEER2 range
8.5–11.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

Multiple source series

SHC24VH2AG

4 published source records

19.2–22.3SEER2 range
10.3–11.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC series

SHC2Z18VC2AG

3 published source records

19–21SEER2 range
9.8–10.2HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC Series

SHC2Z18VE2AG

3 published source records

19–20.5SEER2 range
9–9.3HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC Series

SHC30AB2AB

1 published source record

22.3SEER2 range
9HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC30AH224V

1 published source record

16.8SEER2 range
10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC30AH2AG

2 published source records

20SEER2 range
10.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC series

SHC30VH2AG

1 published source record

20SEER2 range
10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC36AC2AG

1 published source record

20SEER2 range
10.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC36AE224V

1 published source record

16.1SEER2 range
8.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC36AH224V

1 published source record

17.4SEER2 range
10.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC36AH2AG

3 published source records

17.7–21.2SEER2 range
10.6–11.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHD Series

SHC36VH2AG

1 published source record

16.5SEER2 range
11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

SLIMAIRAir-source heat pump

SHC Series

SHC3Z18AC2AG

3 published source records

20–23SEER2 range
10HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC Series

SHC3Z18AH2AG

3 published source records

20–21SEER2 range
10HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC series

SHC3Z27VC2AG

3 published source records

21–23.5SEER2 range
9.2HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC Series

SHC3Z27VE2AG

3 published source records

20–22.6SEER2 range
9.5–9.8HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

SLIMAIRAir-source heat pump

SHC Series

SHC48AC2AG

3 published source records

17.1–19.8SEER2 range
9.8–10.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.