US EQUIPMENT REFERENCE

MAINLINE / page 3

100 equipment models and 630 source-listed options. Brand names follow the published records; a shared manufacturer does not imply interchangeable equipment.

RefineClear

100 models · Source-backed US equipment index

A model may have several rated combinations.
MAINLINEAir-source heat pump

ML Series

ML36HP230LMNTH-O

22 published source records

15.2–18SEER2 range
8.9–10.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

MAINLINEAir-source heat pump

ML Series

ML36HP230MUL - O

3 published source records

20–24SEER2 range
9.2–9.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML36HP230MUL-O

3 published source records

20–23.1SEER2 range
9.2–10HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML36HP230MUL-O*

3 published source records

20–24SEER2 range
9.2–9.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML36HP230MULH - O

3 published source records

19.4–23SEER2 range
10.4–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML36HP230MULH-O

3 published source records

19.4–21.5SEER2 range
10.4–11.3HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML36HP230MULH-O*

3 published source records

19.4–23SEER2 range
10.4–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230LCM-O

8 published source records

17.1–19.8SEER2 range
9.8–10.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

MAINLINEAir-source heat pump

ML Series

ML48HP230LCMH-O

8 published source records

16.7–18.5SEER2 range
10.1–11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

MAINLINEAir-source heat pump

ML Series

ML48HP230LMNT-O

7 published source records

15.2–16SEER2 range
8.5–9HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

MAINLINEAir-source heat pump

ML Series

ML48HP230LMNTH-O

13 published source records

15.2–17.5SEER2 range
8.5–9.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

MAINLINEAir-source heat pump

ML Series

ML48HP230MUL - O

3 published source records

20.4–24SEER2 range
10.3–10.6HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230MUL-O

3 published source records

20.4–21.3SEER2 range
10–10.6HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230MUL-O*

3 published source records

20.4–24SEER2 range
10.3–10.6HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230MULH - O

3 published source records

20.4–23SEER2 range
11HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230MULH-O

3 published source records

20.4–21.2SEER2 range
10.2–11HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML48HP230MULH-O*

3 published source records

20.4–23SEER2 range
11HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML55HP230MULH - O

3 published source records

20–22.2SEER2 range
10.5–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML55HP230MULH-O

3 published source records

20–21.4SEER2 range
10.6–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML55HP230MULH-O*

3 published source records

20–22.2SEER2 range
10.5–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

MAINLINEAir-source heat pump

ML Series

ML60HP230LCMH-O

6 published source records

15.2–18SEER2 range
9.2–10.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.