US EQUIPMENT REFERENCE

Fujitsu / page 2

173 equipment models and 460 source-listed options. Brand names follow the published records; a shared manufacturer does not imply interchangeable equipment.

RefineClear

173 models · Source-backed US equipment index

A model may have several rated combinations.
FujitsuAir-source heat pump

AIRSTAGE H series

AOUH09KPAS1

2 published source records

26SEER2 range
10.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH09KTAP1

4 published source records

33.5SEER2 range
14HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-series

AOUH09KUAS1

1 published source record

24.4SEER2 range
11.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

Multiple source series

AOUH09KUBS1

2 published source records

24.4–26SEER2 range
11.3–11.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH09KZAH1

2 published source records

33.1SEER2 range
13.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH09LEAS1

1 published source record

21.3SEER2 range
10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH09LMAH1

1 published source record

26.5SEER2 range
12.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH09LMAS1

1 published source record

26.5SEER2 range
12.6HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH09LPAS1

1 published source record

20SEER2 range
10.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH09LUAS1

1 published source record

23.5SEER2 range
11.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H series

AOUH12KMAS1

2 published source records

27.5SEER2 range
11.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H series

AOUH12KPAS1

2 published source records

24SEER2 range
10.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH12KTAP1

4 published source records

31.5SEER2 range
13.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

Multiple source series

AOUH12KUAS1

3 published source records

19.1–23.7SEER2 range
10.3–11.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

Multiple source series

AOUH12KUBS1

5 published source records

19.1–25SEER2 range
10.3–11.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH12KZAH1

2 published source records

30.5SEER2 range
12.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH12LMAH1

1 published source record

23SEER2 range
11.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH12LMAS1

1 published source record

23SEER2 range
11.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH12LMBH1

1 published source record

23SEER2 range
11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH12LMBS1

1 published source record

23SEER2 range
11.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

H-Series

AOUH12LUAS1

2 published source records

19.1–23SEER2 range
10.5–11.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH15KTAP1

4 published source records

28.7SEER2 range
13HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH15KZAH1

2 published source records

27.5SEER2 range
12.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

FujitsuAir-source heat pump

AIRSTAGE H-Series

AOUH18KNAS1

1 published source record

20SEER2 range
9HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.